Chicago Data Center

 

NetSource owns and operates our own Chicagoland datacenters providing complete control over quality of service.
NetSource can host your web site, business application, and mission critical data in our state-of-the-art data center. Our hosting solution provides additional value over other service providers since we have direct control and management of the network that is hosting your service. You get the highest in reliability and performance with nearly 100% network availability over the last two years and our 1 gigabit per second fiber bandwidth connection to the Internet. Check out our data center specifications below and see why our Chicago area data center has some of the highest customer ratings in the midwest.

Dedicated Hosting Packages  |  Colocation Packages  |  Shared Hosting Packages  |  Contact NetSource

For more information about our Chicago Land datacenter please continue reading below or contact us at 866.778.1212.

NetSource Datacenter Overview and Specifications
NetSource has almost 15 years experience with business class web hosting. Our newest data center was build in Oct. 2006 and provides the newest technologies and state-of-the-art components. See a complete list of features below:

           Download Specifications Now     Download Presentation Now

Main Network Specifications and Datacenter Features:

  • New on (10/2006) data center was built to ANSI / TIA 942 DATACENTER STANDARDS
  • Many of our customers and clients were audited and passed for HIPPA, Sarbanes-Oxley, and Grahm-Leach-Bliley. NetSource is currently researching SAS-70 standard
  • Built using quality APC database components including racks, cooling, and backup UPS systems
  • Data center is PCI compliant for credit card handling and handling of financial data
  • Multiple POEs (points of entry) for fiber inputs
  • Capacity Planning - No fiber optic link will ever peak at more than 33% of its capacity
  • 1000 MBPS (GigE) fiber connections
  • 100 MBPS connections to NetSource's routers and switches from your server
  • Instant growth and scalability - NetSource can install 96 fiber lines running into the building for possible 95,000 MBPS of bandwidth
  • Redundant bandwidth carriers
  • BGP4 is being used on all border routers to ensure the closest and quickest path between every request
  • 42 U locking cabinets supporting 19" mounting rails
  • 20-amp 120 volt AC circuits, 3-phase circuits available
  • Custom dedicated hosting and managed services available
  • We can work with you on creating a disaster recovery plan using trained specialists
  • Geographically stable (low disaster occurrence) location located 30 miles west of Chicago, Illinois. Located 1/2 mile off I-88 Highway exit for easy access
  • Senior Level system administrators
  • Plus many more features outlined below

NetSource Datacenter

• Newly built 2006 Datacenter
• Gigabit / second fiber bandwidth
• Redundant internet connections
• BGP4 routed for reliability
• UPS power backup
• Generator power backup
• Secure hosting facility
• Constant performance monitoring
• Remote access
• 24x7 physical access

chicago data center - colocation

chicago data center - colocation

Chicago / Naperville Data Center

Datacenter Power Overview

Datacenter GeneratorThe electrical power system is fully redundant uninterruptible power systems (UPS) and a 350 KW Cummins diesel backup generator - minimizing the possibility of power failures.

  • Redundant APC UPS's - uninterruptible power supply battery backups, powers all servers and equipment during generator startup
  • Cummins 350,000 Watt diesel generator - Hospital-grade diesel generator provides for all datacenter operations, and support needs during power outages
  • Dense high capacity circuit distribution
  • 120 VAC and 208 VAC (single and three phase power availability
  • Electrical circuit load monitoring and management



Chicago / Naperville Data Center

AC Power System Specifications

Datacenter APC UPS Backup
  • N+1 Redundancy in all systems
  • Redundant uninterruptible power sources (UPS)
  • APC valve-regulated lead-acid (VRLA) batteries providing a minimum of 5 to 10 minutes backup at full load
  • 24 hour backup with power diesel generator
  • Capable of supporting data center and all equipment
  • Generator backup can be extended with refueling
  • 12 hour re-supply schedule for generator
  • Uninterrupted transfer of power using high capacity UPS and Automatic Transfer Switch (ATS)
  • Transfer of power is completely automatic and transparent in the event of an outage


Chicago / Naperville Data Center

Power System Monitoring and Emergency Plans For Datacenter:

Diesel Generator BackupHigh capacity UPS regularly charges internal battery to sustain enough energy to power servers in any emergency. When an outage occurs, the power is automatically transferred to UPS battery transparent to servers. The power generator is automatically started and the ATS then transfers all data center power to generator source in under 10 seconds.

  • Regularly scheduled maintenance with certified power generator contractors
  • 24/7/365 emergency service with local technician stations
  • 24/7/365 emergency refueling with local provider
  • 24/7/365 monitoring of generator systems at Network Operations Center - NOC


Chicago / Naperville Data Center

Cooling / Environmental Datacenter Specifications:

Cooling and Environmental SystemsThe NetSource datacenter has redundant HVAC systems, so at maximum cooling times, one system can be completely down and not affect room conditions.

  • Redundant HVAC cooling capacity controlled to (+/-) 2 degrees of 70 degrees
  • Leak detection system - upon detection of any water near system, the leak detection will send an alarm
  • Equipped with high capacity HVAC data center grade systems
  • N+1 Redundancy on all cooling systems
  • Data center environment maintained at optimal temperature and humidity levels for equipment
  • 24/7/365 HVAC emergency service by certified contractors
  • Contracted maintenance with certified HVAC contractors
  • Computer controlled humidification system

Chicago / Naperville Data Center

Fire Detection and Suppressions Systems:

FM 200 Fire Suppression SystemThe NetSource data center is protected by dual fire protection systems. NetSource maintains both FM200 waterless fire suppression and Fike dry pipe pre-action fire protection systems, thus allowing NetSource to offer the best available fire protection in existence today.

  • Full fire detection systems installed
  • Photoelectric early warning smoke detectors
  • Heat detection warning systems act as secondary system
  • FM-200 fire suppression system - safe gas based
  • Dual interlock pre-action dry pipe fire suppression systems
  • Water held outside critical equipment areas
  • Assures sprinkler leaks will not damage server equipment
  • High temperature sensors on fire sprinkler heads
  • Fail-safe alarm system to prevent false discharge or tampering
  • Server room has been fire-protected 360 degrees
  • Zone-specific discharge of pre-action systems

Chicago / Naperville Data Center

Security Specifications for Datacenter:

Secure Chicago datacenter NetSource is committed to providing the strongest security to safeguard your equipment 24 hours a day. With multiple levels of security, entry into the data center is restricted by proximity cards and access codes. Video surveillance and stringent data center escort requirements protect server access.

  • Cement building with no windows in datacenter
  • No public access to datacenter
  • No signage describing NetSource's data center services
  • Intrusion detection alarm system
  • Event driven, fixed mount digital Closed Circuit (CCTV) with digital archive
  • All entry, exit, and datacenter locations under surveillance
  • Keycard and Code Access required to enter datacenter
  • Database of individuals authorized to access the facility
  • Man Trap security makes sure only authorized personnel enter data center
  • Secure Chicago datacenter
  • 24/7/365 intrusion detection monitoring
  • Surveillance cameras with 90 days storage
  • Virus Scanning on systems
  • Locked racks for all servers including the availability of secondary locks
  • Serial numbers on equipment is recorded on equipment entry and exit points
  • No smoking, no food, no liquids admitted in datacenter
  • Emergency pager access to all clients for emergency priority
  • No liquids or hazardous materials permitted in the datacenter
  • All access is electronically logged.





Chicago / Naperville Data Center

Operations Control Center Specifications:
Data center control center - NOC
  • State-of-the-art high resolution screen data audio/video system
  • Command consoles for control of local and remote systems
  • Secure, highly restricted access to operations center
  • Monitor and control environmental systems like electrical and cooling
  • Network systems monitoring and management
  • Remote systems for backup monitoring during non business hours
  • NetSource has highly trained system administers on staff
  • Control Center built from the ground up as a datacenter control room




Chicago / Naperville Data Center

Roof Access for Antenna and Cable TV Options:
  • Full roof rights for antenna installations
  • Restricted roof access for special antenna needs
  • We can mount most types of antennas with proper documentation and planning
  • Roof portals for waterproof cable entry so that installation is easy
  • Cable TV can be brought into our center for specific needs

Chicago / Naperville Data Center

Business Conveniences for Visitors:
  • Kitchen access for breaks or longer installs
  • On-site office space setup room that can be reserved
  • Conference room with audio / visual facilities that can be reserved in special cases
  • Fully functioning crash-carts in the datacenter for your use
  • Staffed system administrators to answer your questions

Chicago / Naperville Data Center

Telecommunications Specifications:
  • Access to all major telecommunications providers
  • Redundant true diverse-path, dual entry fiber directly on SONET rings or Gigabit Fiber for highly available, fault-tolerant telecommunications

Chicago / Naperville Data Center

Miscellaneous Building Features:
  • 10 foot ceiling height contributes to maintaining ambient air temp of 70 degrees F
  • 2 foot raised floor for under floor cooling
  • Datacenter is kept clean and dust free to ensure proper equipment functionality
  • Carts available to help customers bring in larger equipment